Sample parameters

SampleParams contains very basic information about the sample - a name and the capacity used for calculating C-rates. These can also be set on protocol export, so a single protocol can be used for many different samples.

Safety parameters

SafetyParams defines the safety limits passed to cyclers - max and min currents and voltages, and/or a capacity limit. delay_s is how long a limit must be exceeded before the cycler cancels the experiment. Biologic caps this at 1 s.

Note that for current limits, Biologic only gives one absolute current limit, it uses the larger of abs(min_current_mA) and abs(max_current_mA) for both directions. Neware accepts two separate values, and the minimum current should be negative if used (otherwise the test may cancel itself immediately).

Recording parameters

RecordParams can be set on the base protocol, or on a particular step.

Parameters on a step will merge with protocol parameters, and override on conflicts. E.g. the protocol has {"time_s": 10, "voltage_V": 0.1} and a step has {"time_s": 1, "current_mA": 0.2}, then the resulting parameters after merge are {"time_s": 1, "voltage_V": 0.1, "current_mA": 0.2}.

Not every condition applies to every step, e.g. a constant voltage step will not apply the voltage_V recording condition.

If no steps have usable recording conditions, converting to a real cycler format will error. PyBaMM and BattINFO do not need recording conditions.

Method

The method is a list of steps: OpenCircuitVoltage, ConstantCurrent, ConstantVoltage, ImpedanceSpectroscopy, VoltageScan, Loop and Tag. See the API Reference for the parameters of each step.

Loops

The best way to define loops is by using tags:

method = [
    Tag(tag="my tag"),
    ...  # some steps
    Loop(loop_to="my tag", cycle_count=100),
]

cycle_count defines the total number of times that loop is performed. A cycle count of 100 means it will jump back to the tag 99 times.

You can have any number of different tags.

Nesting loops works, and the outer loop resets the inner loop counter:

method = [
    Tag(tag="recovery"),
    Tag(tag="longterm"),
    ...  # normal cycling
    Loop(loop_to="longterm", cycle_count=25),
    ...  # recovery step
    Loop(loop_to="recovery", cycle_count=4),
]
This will do 100 (25*4) normal cycles, with 4 recovery steps.

Intersecting loops are ambiguous and not allowed:

method = [
    Tag(tag="A"),
    ...
    Tag(tag="B"),
    ...
    Loop(loop_to="A", cycle_count=10),
    ...
    Loop(loop_to="B", cycle_count=10),
]

Looping to a 1-indexed step is supported (Loop(loop_to=1, cycle_count=100) loops to the 1st step in the list), but it is user-error-prone and not recommended. Tags count as steps in this indexing, e.g. in [Tag, OpenCircuitVoltage, ConstantCurrent, Loop(loop_to=2)] the loop goes back to the OpenCircuitVoltage step.

Looping to tags is strongly recommended. This avoids indexing confusion, and allows you to move steps around without having to recalculate loop conditions.

Tags only exist in the unicycler protocol, the tag text is not kept in e.g. EC-Lab mps or Neware xml files.